What technical details do you need to pay attention to when maintaining the liquid cooling test machine of the energy storage battery cluster

2024-02-02

  When maintaining the storage battery cluster liquid cooling test, you need to pay attention to the following technical details:

  1. Technical details of liquid cooling system:

  1. Ensure that the coolant is used in accordance with the specifications and avoid using incompatible or inferior coolant to prevent corrosion or blockage of the system.

  2, regularly check the coolant conductivity, pH value and impurity content, if necessary to replace or filter.

  3, check the pump and valve in the liquid cooling system to ensure that its sealing and flow performance is good, no leakage or blockage.

  4. Clean the radiator and heat exchanger of the cooling system to maintain its heat dissipation efficiency.

  Second, electrical system technical details:

  1, regularly check the tightness of the electrical connection point to prevent electrical failure caused by loosening.

  2, the use of appropriate test tools to check the insulation resistance and continuity of the circuit to ensure electrical safety.

  3. Check the software version of the control system and update it as needed to ensure compatibility and functionality.

  3. Technical details of mechanical parts:

  1, check the mechanical parts of the fastening bolts and support structure to ensure its stability and reliability.

  2, lubricate mechanical moving parts, such as bearings, guides, etc., to reduce wear and friction resistance.

  3. Monitor the mechanical noise and vibration of the liquid cooling test machine when the energy storage battery cluster is running, detect anomalies in time and take measures.

17006194279392107.jpg

  4. Technical details of sensors and instruments:

  1. Verify the accuracy of key sensors such as temperature sensor, flow sensor and pressure sensor to ensure that the data provided by them is reliable.

  2, regularly check the function of the display instrument and control panel to ensure that it works normally and accurately displays parameters.

  5. Anti-corrosion and anti-rust technical details:

  1, regular anti-rust treatment of metal parts, such as applying anti-rust agent or surface coating protection.

  2, check the storage battery cluster liquid cooling test machine shell and internal structure of the anti-corrosion coating, if there is damage should be repaired in time.

  6. Software and Firmware technical details:

  1, regularly check the storage battery cluster liquid cooling test machine software and firmware version, and update according to the manufacturer's recommendation.

  2, ensure that the test software is compatible with the equipment hardware, and correctly configure the test parameters and calibration data.

  7. Technical details of environmental monitoring:

  1. Monitor the temperature, humidity and cleanliness of the surrounding environment of the equipment to ensure that it is within the working range of the equipment.

  2. Install environmental control devices such as air filters, fans, and air conditioners as required to ensure the stable operation of the devices.